ASCN - STATION INSTRUMENTATION
3. Global Seismograph Network - GSN:
DATES OF OPERATION: 09 Nov 2003 to 21 May 2009.
SEISMOMETER TYPE AND ADC:
Teledyne Brown model KS-54000 borehole 3 component system for broadband,
long period, and very long period channels recorded at 20 sps, 1 sps and
0.1 sps respectively. Guralp systems model CMG-3T 3 component seismometer
for short period, long period, and very long period channels recorded at 40 sps,
1 sps and 0.1 sps respectively. Kinemetrics FBA-23 3-component force
balance accelerometer recorded at 1 sps continuous mode and at 100 sps
triggered mode. IDA MK8 data aquisition system.
CALIBRATION EPOCHS: 2003, 313 - 2009, 141
DIGITAL FORMAT: 32 bit integer data words for broadband (20 sps), long period
(1 sps), very long period (.1 sps), and short period (40 sps) channels. 16-bit
integer data words for extremely short period (100 sps) triggered channels.
Click on any of the following items for further information.